BI-400, 675, 1000 & 1500 ELECTRIC ACTUATOR

Output torque BI-400 . . . 400 inch pounds
BI-675 . . . 675 inch pounds
BI-1000 . . .1000 inch pounds
BI-1500 . . .1500 inch pounds
Cycle time BI-400 . . . 10 sec/90°
BI-675/1000 . . . 15 sec/90°
BI-1500 . . . 30 sec/90°
Duty cycle 25%
Standard motor 115VAC/1ph/60hz
Standard enclosure NEMA 4
Enclosure material Aluminum
Enclosure coating Thermal bonding polyester powder
Temperature rating -40°F to +150°F*
Thermal overload protection Standard
Manual override Standard declutchable
Lock rotor current BI-400/675 . . . 0.75 amps
BI-1000/1500 . . . .1.1 amps
Switches 15A, 1/2 HP
125/250VAC/0.5A/125VDC
Weight 13 pounds
*Heater required below 0°F
DIMENSIONAL INFORMATION FOR BI-400 THROUGH 1500

PERFORMANCE SPECIFICATIONS FOR
BI-400 THROUGH 1500

PARTS LIST FOR BI-400/675/1000/1500

BACK TO ELECTRIC ACTUATOR MAIN PAGE

SPECIFICATIONS FOR 115VAC ACTUATOR