PERFORMANCE RATINGS FOR BI-TORQ ELECTRIC ACTUATORS

VOLTAGE 115VAC 24VDC 24VAC 12VDC 220VAC
PART NUMBER BI-100-A-4 BI-100-B-4 BI-100-C-4 BI-100-F-4 BI-100-H-4
CYCLE TIME 2.5 SECONDS 3 SECONDS 3 SECONDS 3 SECONDS 2.5 SECONDS
DUTY CYCLE 75% 75% 75% 75% 75%
AMP DRAW 0.55 2.44/0.4 2.44/0.4 2.89/0.6 0.38
BI-100 Series
BI-200 and 300 Series
VOLTAGE 115VAC 24VDC 24VAC 12VDC 220VAC
PART NUMBER BI-***-A-4 BI-***-B-4 BI-***-C-4 BI-***-F-4 BI-***-H-4
CYCLE TIME 5 SECONDS 10 SECONDS 10 SECONDS 10 SECONDS 5 SECONDS
DUTY CYCLE 25% 75% 75% 75% 25%
AMP DRAW 0.75 3.2/0.8 3.2/0.8 4.0/1.4 0.38
***use 200 or 300
BI-400 Series
VOLTAGE 115VAC 24VDC 24VAC 12VDC 220VAC
PART NUMBER BI-400-A-4 BI-400-B-4 BI-400-C-4 BI-400-F-4 BI-400-H-4
CYCLE TIME 10 SECONDS 20 SECONDS 20 SECONDS 20 SECONDS 10 SECONDS
DUTY CYCLE 25% 75% 75% 75% 25%
AMP DRAW 0.75 3.2/0.8 3.2/0.8 4.00/1.4 0.38
BI-675 or 1000 Series
VOLTAGE 115VAC 24VDC 24VAC 12VDC 220VAC
PART NUMBER BI-***-A-4 BI-***-B-4 BI-***-C-4 BI-***-F-4 BI-***-H-4
CYCLE TIME 15 SECONDS 30 SECONDS 30 SECONDS 30 SECONDS 15 SECONDS
DUTY CYCLE 25% 75% 75% 75% 25%
AMP DRAW 1.10 3.2/0.8 3.2/0.8 4.00/1.4 0.38
BI-1500 Series
VOLTAGE 115VAC 24VDC 24VAC 12VDC 220VAC
PART NUMBER BI-1500-A-4 BI-1500-B-4 BI-1500-C-4 BI-1500-F-4 BI-1500-H-4
CYCLE TIME 30 SECONDS 60 SECONDS 60 SECONDS 60 SECONDS 30 SECONDS
DUTY CYCLE 25% 75% 75% 75% 25%
AMP DRAW 1.10 3.2/0.8 3.2/0.8 4.00/1.4 0.38
BI-2000 Series
VOLTAGE 115VAC 24VDC 24VAC 12VDC 220VAC
PART NUMBER BI-2000-A-4 BI-2000-B-4 BI-2000-C-4 BI-2000-F-4 BI-2000-H-4
CYCLE TIME 12 SECONDS 12 SECONDS 12 SECONDS 12 SECONDS 12 SECONDS
DUTY CYCLE 100% 100% 100% 100% 100%
AMP DRAW 2.60/0.98 14/20 14/20 14 2.80/1.30
BI-3800 Series
VOLTAGE 115VAC 24VDC 24VAC 12VDC 220VAC
PART NUMBER BI-3800-A-4 BI-3800-B-4 BI-3800-C-4 BI-3800-F-4 BI-3800-H-4
CYCLE TIME 12 SECONDS 12 SECONDS 12 SECONDS 12 SECONDS 12 SECONDS
DUTY CYCLE 100% 100% 100% 100% 100%
AMP DRAW 2.60/0.98 14/20 14/20 14 2.80/1.30
extended duty cycle motors are available on most models with AC motors (doubles cycle time)
DC motors require reversing relay (not included)
***use 675 or 1000